ICP-OES ASTM D5185 /ASTM D4951/ ISO 22241 Annex I |
CCS ASTM D5293 |
ASTM D5293 ASTM D2983 |
|
TAN Analyser ASTM D664 |
TBN Analyser ASTM D2896/ASTM D4739 |
Nitrogen Analyser ASTM D4629 / ASTM D5762 |
|
Sulfur Analyser ASTM D5453 |
FTIR ASTM E2412/ ASTM D7414/ASTM D7624/ ISO 22241 Annex J |
Pour Point Tester ASTM D97 |
|
Cloud Point Tester ASTM D2500 |
Water Separability ASTM D1401 |
Foaming Characteristics ASTM D892 |
|
Kinematic Viscosity ASTM D445/ASTM D446 |
Karl Fisher Analyser ASTM D6304 |
Pour Point Tester ASTM D97 |
|
Four Ball Weld Load ASTM D4172, ASTM D2783 |
Panel Coker FTM 791 |
TEOST (MHT) ASTM D7097 |
|
HTHS ASTM D4683 |
Particle Counter NAS 1638/ISO 4406 |
COC Flash point tester ASTM D92/ ISO 2592 |
|
PMCC Flash point tester ASTM D93/ ISO 2719 |
Densitometer ASTM D4052/ ISO 12185 |
Refractometer ISO 22241 - Annex C |
|
UV Visible spectroscopy ISO 22241 - Annex E / Annex F/ Annex H |
Brookfield Viscometer ASTM D2983 |
Noack Volatality ASTM D5800(B) |
|
Distillation ASTMD86 /ASTM D1078 |
Chloride Analyser ASTM D4929(B) / UOP 779 |
|
Execution of Field Trials as per customers tailor made requirements with industry accepted validation protocols in terms of below Functions and activities
| Functions | Activities |
|---|---|
| Sampling Protocol | Provide SOPs and training for correct oil sample collection and labelling. |
| Baseline Comparison | Analyse fresh oil to establish reference; compare with used oil to assess degradation. |
| Oil Sample Analysis | Test for wear metals, viscosity, oxidation, TBN, soot, water, fuel dilution to assess oil condition |
| Troubleshooting Support | Investigate failures and assist with root cause analysis subject to lubricant |
| Test Report | It Confirms the continuous real time health check of the oil and its corresponding application. |
| Performance Validation | Confirms whether candidate oil meets required OEM and industry specifications like API,ACEA,ILSAC |